4-Tech PIM

Industrial Catalog

cleco-rukovodstvo-po-vosstanovleniyu-i-ustanovke-mpro400gc.pdf

cleco-rukovodstvo-po-vosstanovleniyu-i-ustanovke-mpro400gc

Cleco

Documentation Recovery / Installation System
for mPro400GC
S169372
Image
Image
Software S169372-103

Contents

Topic Page

1 Overview .............................................................................................................................................. 3

2 Prerequisites ....................................................................................................................................... 3

3 Starting the Installation System ........................................................................................................ 4

4 Available Options ............................................................................................................................... 4

Image
1 Overview

Remark

Version S169372-103 Languages English Functions Installation of the internal CF-Card to get a bootable system

2 Prerequisites

This software works only on an mPro400GC controller. The software must be copied onto a (preferably blank) USB stick. A USB keyboard must be connected to the controller.

2.1 Creating the Recovery / Installation USB stick

To make USB stick bootable, unpack the contents of the provided zip-file onto the root folder of the stick. After unpacking, it should look like this:

Image
Image
3 Starting the Installation System

To start the installation system, an empty CF card must be inserted and the USB stick must be connected to one of the USB ports. Switch on the Controller, and it boots from the USB stick. After that, you will see the menu described below:

Available Options
4.1 Restore previous software version

If something went wrong with the last software installation, the last backup can be restored by using this option.

4.2 Reinstall CF Card

With this option, the internal CF card will be partitioned and formatted. After that, the default software version will be installed This option should be used with CF cards bigger than 128 MB. The previously installed mPro Software, Parameters and Rundown data will be de- leted!

4.3 Reinstall System Partition

With this option, the default software will be installed on the first partition of the CF card. All data stored on the second partition (e.g. Rundown data and Parameters) will stay on the con- troller. Besides that, the parameters of the current mPro software will be restored. After that, the mPro software has to be re-installed.

4.4 Reinstall System Partition (without deleting software package)

With this option, the default software will be installed on the first partition of the CF card. All data stored on the second partition (e.g. Rundown data and Parameters) will stay on the con- troller. Besides that, the parameters and the current mPro software will be restored.

Image
Image
4.5 Restore Factory Default Parameters

All Parameter Changes will be reverted to Factory Defaults provided with the software pack- age.

4.6 Update Boot loader

The latest Boot loader software will be flashed into EEPROM.

4.7 Reboot

After selecting this option, the system should be restarted.

Image